Functional Safety Documentation: What Auditors Ask For

Published: Publisher: Zhilianhai Robotics News

The four documents

DocumentContent
Safety requirements specificationFunctions, required PL/SIL, reaction times
Design fileArchitecture, components with declared PL/SIL, wiring
Verification recordCalculation plus measured stopping times
Validation recordEach function tested, dated, signed

Questions that expose weak files

  • Which standard edition did you apply, and why?
  • How was the required performance level derived?
  • Show the measurement of the achieved stopping time.
  • What changed since the last validation?

A calculation that does not match the wiring on the machine fails audit. Keep as-built drawings in the same folder as the calculation.